Data Editing#

Important

On this page, perform settings in the order: Start Setup -> Function Parameter Barcode -> End Setup.

Output format#

The following is the data output format.

Field

Length / Description

Barcode Information

4 bytes

Prefix

4 bytes

AIM ID

Barcode Data

Suffix

4 bytes

Terminator

1 byte

Barcode Information#

Important

For this procedure, perform settings in the order: Start Setup -> Function Parameter Barcode -> End Setup.

  1. By default, barcode information is not output.

  2. Use a serial command or scan a Parameter Barcode to enable or disable barcode information output.

Warning

This function is supported only in serial mode and is not supported in USB keyboard mode.

The format is defined as follows:

Field

Length / Description

Start Flag

0x03 (1 byte)

Barcode Symbology Code

1 byte, hexadecimal

Barcode Length

2 bytes, range 0x0001 ~ 0xFFFF

Barcode symbology codes are as follows:

Code

Barcode Types

0x41

PDF417

0x42

MicroPDF417

0x43

Data Matrix

0x44

QR Code

0x45

Micro QR

0x46

Aztec

0x47

MaxiCode

0x61

UPC-A

0x62

UPC-E

0x63

EAN-8

0x64

EAN-13

0x65

Code 128

0x66

Code 39

0x67

Code 93

0x68

Code 32

0x69

Code 11

0x6A

Codabar

0x6B

Plessey

0x6C

MSI Plessey

0x6D

Interleaved 2 of 5

0x6E

IATA 2 of 5

0x6F

Matrix 2 of 5

0x70

Straight 2 of 5

0x71

Pharmacode

0x72

GS1 DataBar 14

0x73

GS1 DataBar Expanded

0x74

GS1 DataBar Limited

0x75

Composite Code-A

0x76

Composite Code-B

0x77

Composite Code-C

../../_shared/_images/module-280/24I0.png

* Disable#

../../_shared/_images/module-280/24I1.png

Enable#

Prefix#

Important

For this procedure, perform settings in the order: Start Setup -> Function Parameter Barcode -> End Setup.

Add output characters before barcode data. Up to 4 characters can be set.

Example: Add the character a before all barcode data

  1. Scan “Start Setup”.

  2. Scan the “Set Prefix for All Symbologies” Parameter Barcode.

  3. Scan the a Parameter Barcode in ASCII Code Table.

  4. Scan “End Setup”.

Example: Remove the prefix

  1. Scan “Start Setup”.

  2. Scan the “Disable Prefix for All Symbologies” Parameter Barcode.

  3. Scan “End Setup”.

Example: Add the characters &13 before EAN-13 barcode data

  1. Scan “Start Setup”.

  2. Scan the “Set EAN-13 Prefix” Parameter Barcode.

  3. Scan the & Parameter Barcode in ASCII Code Table.

  4. Scan the 1 Parameter Barcode in ASCII Code Table.

  5. Scan the 3 Parameter Barcode in ASCII Code Table.

  6. Scan “End Setup”.

Example: Remove the EAN-13 prefix

  1. Scan “Start Setup”.

  2. Scan the “Disable EAN-13 Prefix” Parameter Barcode.

  3. Scan “End Setup”.

../../_shared/_images/module-280/DP00.png

* Disable Prefix for All Symbologies#

../../_shared/_images/module-280/EP00.png

Set Prefix for All Symbologies#

../../_shared/_images/module-280/EP01.png

Set UPC-A Prefix#

../../_shared/_images/module-280/DP01.png

Disable UPC-A Prefix#

../../_shared/_images/module-280/EP02.png

Set UPC-E Prefix#

../../_shared/_images/module-280/DP02.png

Disable UPC-E Prefix#

../../_shared/_images/module-280/EP03.png

Set EAN-8 Prefix#

../../_shared/_images/module-280/DP03.png

Disable EAN-8 Prefix#

../../_shared/_images/module-280/EP04.png

Set EAN-13 Prefix#

../../_shared/_images/module-280/DP04.png

Disable EAN-13 Prefix#

../../_shared/_images/module-280/EP05.png

Set Code 128 Prefix#

../../_shared/_images/module-280/DP05.png

Disable Code 128 Prefix#

../../_shared/_images/module-280/EP06.png

Set Code 39 Prefix#

../../_shared/_images/module-280/DP06.png

Disable Code 39 Prefix#

../../_shared/_images/module-280/EP07.png

Set Code 93 Prefix#

../../_shared/_images/module-280/DP07.png

Disable Code 93 Prefix#

../../_shared/_images/module-280/EP08.png

Set Code 32 Prefix#

../../_shared/_images/module-280/DP08.png

Disable Code 32 Prefix#

../../_shared/_images/module-280/EP09.png

Set Code 11 Prefix#

../../_shared/_images/module-280/DP09.png

Disable Code 11 Prefix#

../../_shared/_images/module-280/EP10.png

Set Codabar Prefix#

../../_shared/_images/module-280/DP10.png

Disable Codabar Prefix#

../../_shared/_images/module-280/EP11.png

Set Plessey Prefix#

../../_shared/_images/module-280/DP11.png

Disable Plessey Prefix#

../../_shared/_images/module-280/EP12.png

Set MSI Plessey Prefix#

../../_shared/_images/module-280/DP12.png

Disable MSI Plessey Prefix#

../../_shared/_images/module-280/EP13.png

Set Interleaved 2 of 5 Prefix#

../../_shared/_images/module-280/DP13.png

Disable Interleaved 2 of 5 Prefix#

../../_shared/_images/module-280/EP14.png

Set IATA 2 of 5 Prefix#

../../_shared/_images/module-280/DP14.png

Disable IATA 2 of 5 Prefix#

../../_shared/_images/module-280/EP15.png

Set Matrix 2 of 5 Prefix#

../../_shared/_images/module-280/DP15.png

Disable Matrix 2 of 5 Prefix#

../../_shared/_images/module-280/EP16.png

Set Straight 2 of 5 Prefix#

../../_shared/_images/module-280/DP16.png

Disable Straight 2 of 5 Prefix#

../../_shared/_images/module-280/EP17.png

Set Pharmacode Prefix#

../../_shared/_images/module-280/DP17.png

Disable Pharmacode Prefix#

../../_shared/_images/module-280/EP18.png

Set GS1 DataBar 14 Prefix#

../../_shared/_images/module-280/DP18.png

Disable GS1 DataBar 14 Prefix#

../../_shared/_images/module-280/EP19.png

Set GS1 DataBar Expanded Prefix#

../../_shared/_images/module-280/DP19.png

Disable GS1 DataBar Expanded Prefix#

../../_shared/_images/module-280/EP20.png

Set GS1 DataBar Limited Prefix#

../../_shared/_images/module-280/DP20.png

Disable GS1 DataBar Limited Prefix#

../../_shared/_images/module-280/EP21.png

Set Composite Code A Prefix#

../../_shared/_images/module-280/DP21.png

Disable Composite Code A Prefix#

../../_shared/_images/module-280/EP22.png

Set Composite Code B Prefix#

../../_shared/_images/module-280/DP22.png

Disable Composite Code B Prefix#

../../_shared/_images/module-280/EP23.png

Set Composite Code C Prefix#

../../_shared/_images/module-280/DP23.png

Disable Composite Code C Prefix#

../../_shared/_images/module-280/EP24.png

Set PDF417 Prefix#

../../_shared/_images/module-280/DP24.png

Disable PDF417 Prefix#

../../_shared/_images/module-280/EP25.png

Set MicroPDF417 Prefix#

../../_shared/_images/module-280/DP25.png

Disable MicroPDF417 Prefix#

../../_shared/_images/module-280/EP26.png

Set Data Matrix Prefix#

../../_shared/_images/module-280/DP26.png

Disable Data Matrix Prefix#

../../_shared/_images/module-280/EP27.png

Set QR Code Prefix#

../../_shared/_images/module-280/DP27.png

Disable QR Code Prefix#

../../_shared/_images/module-280/EP28.png

Set Micro QR Prefix#

../../_shared/_images/module-280/DP28.png

Disable Micro QR Prefix#

../../_shared/_images/module-280/EP29.png

Set Aztec Prefix#

../../_shared/_images/module-280/DP29.png

Disable Aztec Prefix#

../../_shared/_images/module-280/EP30.png

Set MaxiCode Prefix#

../../_shared/_images/module-280/DP30.png

Disable MaxiCode Prefix#

Suffix#

Important

For this procedure, perform settings in the order: Start Setup -> Function Parameter Barcode -> End Setup.

Add output characters after barcode data. Up to 4 characters can be set.

Example: Add the character a after all barcode data

  1. Scan “Start Setup”.

  2. Scan the “Set Suffix for All Symbologies” Parameter Barcode.

  3. Scan the a Parameter Barcode in ASCII Code Table.

  4. Scan “End Setup”.

Example: Remove the suffix

  1. Scan “Start Setup”.

  2. Scan the “Disable Suffix for All Symbologies” Parameter Barcode.

  3. Scan “End Setup”.

Example: Add the characters &13 after EAN-13 barcode data

  1. Scan “Start Setup”.

  2. Scan the “Set EAN-13 Suffix” Parameter Barcode.

  3. Scan the & Parameter Barcode in ASCII Code Table.

  4. Scan the 1 Parameter Barcode in ASCII Code Table.

  5. Scan the 3 Parameter Barcode in ASCII Code Table.

  6. Scan “End Setup”.

Example: Remove the EAN-13 suffix

  1. Scan “Start Setup”.

  2. Scan the “Disable EAN-13 Suffix” Parameter Barcode.

  3. Scan “End Setup”.

../../_shared/_images/module-280/ES00.png

Set Suffix for All Symbologies#

../../_shared/_images/module-280/DS00.png

* Disable Suffix for All Symbologies#

../../_shared/_images/module-280/ES01.png

Set UPC-A Suffix#

../../_shared/_images/module-280/DS01.png

Disable UPC-A Suffix#

../../_shared/_images/module-280/ES02.png

Set UPC-E Suffix#

../../_shared/_images/module-280/DS02.png

Disable UPC-E Suffix#

../../_shared/_images/module-280/ES03.png

Set EAN-8 Suffix#

../../_shared/_images/module-280/DS03.png

Disable EAN-8 Suffix#

../../_shared/_images/module-280/ES04.png

Set EAN-13 Suffix#

../../_shared/_images/module-280/DS04.png

Disable EAN-13 Suffix#

../../_shared/_images/module-280/ES05.png

Set Code 128 Suffix#

../../_shared/_images/module-280/DS05.png

Disable Code 128 Suffix#

../../_shared/_images/module-280/ES06.png

Set Code 39 Suffix#

../../_shared/_images/module-280/DS06.png

Disable Code 39 Suffix#

../../_shared/_images/module-280/ES07.png

Set Code 93 Suffix#

../../_shared/_images/module-280/DS07.png

Disable Code 93 Suffix#

../../_shared/_images/module-280/ES08.png

Set Code 32 Suffix#

../../_shared/_images/module-280/DS08.png

Disable Code 32 Suffix#

../../_shared/_images/module-280/ES09.png

Set Code 11 Suffix#

../../_shared/_images/module-280/DS09.png

Disable Code 11 Suffix#

../../_shared/_images/module-280/ES10.png

Set Codabar Suffix#

../../_shared/_images/module-280/DS10.png

Disable Codabar Suffix#

../../_shared/_images/module-280/ES11.png

Set Plessey Suffix#

../../_shared/_images/module-280/DS11.png

Disable Plessey Suffix#

../../_shared/_images/module-280/ES12.png

Set MSI Plessey Suffix#

../../_shared/_images/module-280/DS12.png

Disable MSI Plessey Suffix#

../../_shared/_images/module-280/ES13.png

Set Interleaved 2 of 5 Suffix#

../../_shared/_images/module-280/DS13.png

Disable Interleaved 2 of 5 Suffix#

../../_shared/_images/module-280/ES14.png

Set IATA 2 of 5 Suffix#

../../_shared/_images/module-280/DS14.png

Disable IATA 2 of 5 Suffix#

../../_shared/_images/module-280/ES15.png

Set Matrix 2 of 5 Suffix#

../../_shared/_images/module-280/DS15.png

Disable Matrix 2 of 5 Suffix#

../../_shared/_images/module-280/ES16.png

Set Straight 2 of 5 Suffix#

../../_shared/_images/module-280/DS16.png

Disable Straight 2 of 5 Suffix#

Warning

The image labelled “Set Pharmacode Suffix” in the historical source actually decodes to KM15 (Slovak keyboard layout). To prevent incorrect configuration, this Parameter Barcode is not provided here. The intended command must be confirmed independently by the product or firmware owner.

../../_shared/_images/module-280/DS17.png

Disable Pharmacode Suffix#

../../_shared/_images/module-280/ES18.png

Set GS1 DataBar 14 Suffix#

../../_shared/_images/module-280/DS18.png

Disable GS1 DataBar 14 Suffix#

../../_shared/_images/module-280/ES19.png

Set GS1 DataBar Expanded Suffix#

../../_shared/_images/module-280/DS19.png

Disable GS1 DataBar Expanded Suffix#

../../_shared/_images/module-280/ES20.png

Set GS1 DataBar Limited Suffix#

../../_shared/_images/module-280/DS20.png

Disable GS1 DataBar Limited Suffix#

../../_shared/_images/module-280/ES21.png

Set Composite Code A Suffix#

../../_shared/_images/module-280/DS21.png

Disable Composite Code A Suffix#

../../_shared/_images/module-280/ES22.png

Set Composite Code B Suffix#

../../_shared/_images/module-280/DS22.png

Disable Composite Code B Suffix#

../../_shared/_images/module-280/ES23.png

Set Composite Code C Suffix#

../../_shared/_images/module-280/DS23.png

Disable Composite Code C Suffix#

../../_shared/_images/module-280/ES24.png

Set PDF417 Suffix#

../../_shared/_images/module-280/DS24.png

Disable PDF417 Suffix#

../../_shared/_images/module-280/ES25.png

Set MicroPDF417 Suffix#

../../_shared/_images/module-280/DS25.png

Disable MicroPDF417 Suffix#

../../_shared/_images/module-280/ES26.png

Set Data Matrix Suffix#

../../_shared/_images/module-280/DS26.png

Disable Data Matrix Suffix#

../../_shared/_images/module-280/ES27.png

Set QR Code Suffix#

../../_shared/_images/module-280/DS27.png

Disable QR Code Suffix#

../../_shared/_images/module-280/ES28.png

Set Micro QR Suffix#

../../_shared/_images/module-280/DS28.png

Disable Micro QR Suffix#

../../_shared/_images/module-280/ES29.png

Set Aztec Suffix#

../../_shared/_images/module-280/DS29.png

Disable Aztec Suffix#

../../_shared/_images/module-280/ES30.png

Set MaxiCode Suffix#

../../_shared/_images/module-280/DS30.png

Disable MaxiCode Suffix#

Code ID#

Important

For this procedure, perform settings in the order: Start Setup -> Function Parameter Barcode -> End Setup.

../../_shared/_images/module-280/24D0.png

* Disable Code ID#

../../_shared/_images/module-280/24D1.png

Enable AIM Code ID#

../../_shared/_images/module-280/24D2.png

Enable NETUM Code ID#

Code ID Table

Symbology

NETUM

AIM

UPC-A

A

E

UPC-E

E

E

EAN-8

FF

E

EAN-13

F

E

Code 128

K

C

Code 39

M

A

Code 93

L

G

Code 32

M

A

Code 11

O

H

Codabar

N

F

Plessey

P

P

MSI / Plessey

a

M

Interleaved 2 of 5

I

I

IATA 2 of 5

Z

R

Matrix 2 of 5

G

X

Straight 2 of 5

S

S

Pharmacode

H

X

GS1 DataBar 14

RS

e

GS1 DataBar Expanded

RX

e

GS1 DataBar Limited

RL

e

Composite CC-A

m

e

Composite CC-B

n

e

Composite CC-C

i

e

PDF417

r

L

MicroPDF417

s

L

Data Matrix

t

d

QR Code

u

Q

Micro QR

j

Q

Aztec

e

Z

MaxiCode

v

U

Terminator#

Important

For this procedure, perform settings in the order: Start Setup -> Function Parameter Barcode -> End Setup.

../../_shared/_images/module-280/TC01.png

none#

../../_shared/_images/module-280/TC03.png

* Carriage Return / CR#

../../_shared/_images/module-280/TC02.png

CR / LF#

../../_shared/_images/module-280/TC04.png

TAB#