Anhang und Setup-Code#

Parameter-Standardtabelle#

Parameter-Standardwert#

In dieser Tabelle sind typische Standardparameter für jedes Kapitel aufgeführt:

Parameter

Standardwert

Transmit Code ID Character

None

Scan Data Transmission Format

Data As Is

FN1 Substitution Value

7013 (Enter)

Transmit "No Read" Message

Disable

Standardwert der USB-Schnittstelle#

Zu den Standardwerten der USB-Schnittstelle gehören:

Parameter

Standardwert

USB Device Type

SNAPI with Imaging

SNAPI Status Handshaking

Enable

USB Country Keyboard Types

North American

USB Keystroke Delay

No Delay

Simulated Caps Lock

Disable

USB CAPS Lock Override

Disable

USB Ignore Unknown Characters

Enable

USB Convert Unknown to Code 39

Disable

USB Ignore Beep Directive

Follow Host Directive

USB Ignore Type Directive

Follow Host Directive

Emulate Keypad

Disable

Emulate Keypad with Leading Zero

Disable

USB FN1 Substitution

Disable

Function Key Mapping

Disable

Convert Case

None

USB Static CDC

Enable

USB Polling Interval

8 msec

Quick Keypad Emulation

Disable

Standardtabelle für die Simulation von Lesegeräten für nicht dekodierten Code#

wird verwendet, um die Standard-Hostparameter im Emulationsmodus des nicht dekodierten Barcode-Lesegeräts zu archivieren. Dieser Modus wird normalerweise mit einem bestimmten Terminal- oder Hostprotokoll verwendet. Sie sollten den aktuellen Hostschnittstellentyp bestätigen, bevor Sie ihn ändern.

RS232-Host-Standardtabelle#

Für Standard-RS232 gelten folgende Standardwerte:

Parameter

Standardwert

Serial Host Types

Standard RS-232

Baud Rate

9600

Parity Type

None

Stop Bits

1

Data Bits

8-Bit

Check Receive Errors

Enable

Hardware Handshaking

None

Software Handshaking

None

Host Serial Response Time-out

2 Sec

RTS Line State

Low RTS

Beep on <BEL>

Disable

Intercharacter Delay

0 msec

Nixdorf Beep/LED Options

Normal Operation

Ignore Unknown Characters

Send barcode

Befehls- und Ereignistabelle#

SSI-Befehlstabelle#

In diesem Abschnitt werden SSI-Befehlsnummern, Befehlsnamen, Parameterlängen und Beispieldaten aufgeführt.

Ereigniscodetabelle#

In diesem Abschnitt werden die Ereignisnummer, der Ereignisname und die Beschreibung der Auslösebedingung aufgeführt.

Terminalspezifische Code ID-Zeichentabelle#

In dieser Tabelle sind die festen Code ID-Zeichen in jedem Terminalmodus aufgeführt.

Bemerkung

Wenn als Hosttyp ICL, Fujitsu, Wincor-Nixdorf, OPOS/JPOS, Olivetti, Omron oder CUTE gewählt ist, aktiviert das Gerät automatisch die terminalspezifische Code ID aus dieser Tabelle. Diese Werte sind nicht programmierbar und von Transmit Code ID unabhängig; „Transmit Code ID Character“ darf daher nicht zusätzlich aktiviert werden.

Um horizontales Zuschneiden auf Mobilgeräten zu vermeiden, ist die Tabelle nach Terminaltyp aufgeteilt.

Code Type

ICL

Fujitsu

UPC-A

AA

A

UPC-E

EE

C

EAN-8/JAN-8

FF

FF

EAN-13/JAN-13

FF

A

Bookland EAN

FF

A

Code 39

C<len>

None

Code 39 Full ASCII

None

None

Trioptic

None

None

Code 32

None

None

Codabar

N<len>

None

Code 128

L<len>

None

GS1-128

L<len>

None

Code 93

None

None

I 2 of 5

I<len>

None

D 2 of 5

H<len>

None

MSI

None

None

Code 11

None

None

IATA

H<len>

None

GS1 DataBar Variants

None

None

PDF417

None

None

MicroPDF417

None

None

Data Matrix

None

None

Maxicode

None

None

QR Codes

None

None

Aztec/Aztec Rune

None

None

Code Type

Wincor-Nixdorf Mode A

Wincor-Nixdorf Mode B / OPOS/JPOS

UPC-A

A

A

UPC-E

C

C

EAN-8/JAN-8

B

B

EAN-13/JAN-13

A

A

Bookland EAN

A

A

Code 39

M

M

Code 39 Full ASCII

M

M

Trioptic

None

None

Code 32

None

None

Codabar

N

N

Code 128

K

K

GS1-128

P

P

Code 93

L

L

I 2 of 5

I

I

D 2 of 5

H

H

MSI

O

O

Code 11

None

None

IATA

H

H

GS1 DataBar Variants

E

E

PDF417

Q

Q

MicroPDF417

S

S

Data Matrix

R

R

Maxicode

T

T

QR Codes

U

U

Aztec/Aztec Rune

V

V

Code Type

Olivetti

Omron

CUTE

UPC-A

A

A

-

UPC-E

E

None

-

EAN-8/JAN-8

B

FF

None

EAN-13/JAN-13

F

A

-

Bookland EAN

F

None

-

Code 39

M<len>

C<len>

3

Code 39 Full ASCII

None

None

3

Trioptic

None

None

None

Code 32

None

None

None

Codabar

N<len>

N<len>

None

Code 128

K<len>

L<len>

5

GS1-128

P<len>

L<len>

5

Code 93

L<len>

None

None

I 2 of 5

I<len>

I<len>

1

D 2 of 5

H<len>

H<len>

2

MSI

O<len>

None

None

Code 11

None

None

None

IATA

H<len>

H<len>

2

GS1 DataBar Variants

None

None

None

PDF417

None

None

6

MicroPDF417

None

None

6

Data Matrix

None

None

4

Maxicode

None

None

None

QR Codes

None

None

7

Aztec/Aztec Rune

None

None

8

Tabelle mit Suffixen, Suffixen und Zeichenwerten#

Präfix-/Suffix-Wertetabelle#

Wichtige Punkte:

  • Prefix/Suffix Values, festgelegt durch 4 Ziffern

  • Das erste Bit ist der Schlüsseltyp

  • Die letzten 3 Ziffern sind Dezimalzeichenwerte

  • Eine detaillierte Wertetabelle finden Sie in Table E-1.

Unter einigen Terminal-Standardparametern sind typische Standardwerte für Suffixe und Suffixe:

  • STX (1002)

  • CR (1013)

  • ETX (1003)

USB-ASCII-Zeichensatztabelle#

Dieser Abschnitt entspricht Table 8-2 USB Prefix/Suffix Values und enthält die Präfix-, Suffix- und Steuerzeichenzuordnungen von 1000 bis 1126. Er kann für Folgendes verwendet werden:

  • Präfix- und Suffixeinstellungen

  • FN1 Ersatzwertauswahl

  • USB-Tastatur-Steuerzeichenausgabe

Nationaler Tastaturtypcode#

Dieser Abschnitt entspricht der Auswahl des USB HID Keyboardlayouts und listet häufig verwendete Tastaturlayoutcodes auf. Die vollständigen Setup-Codes werden durch USB- und Tastatureinstellungen im PL5-Modulhandbuch verwaltet.

Tastaturlayout

Setup-Code

North American Standard USB Keyboard

SXUAH20100

German Windows

SXUAH2010A

French Windows

SXUAH20109

French Canadian Windows 95/98

SXUAH2010B

French Canadian Windows 2000/XP

SXUAH20111

French Belgian Windows

SXUAH20108

Spanish Windows

SXUAH2010C

Italian Windows

SXUAH2010D

Swedish Windows

SXUAH2010E

UK English Windows

SXUAH2010F

Japanese Windows (ASCII)

SXUAH20110

Portuguese-Brazilian Windows

SXUAH20112

Tabelle mit Hexadezimalwerten#

Mit dieser Tabelle wird die Entsprechung zwischen Hexadezimalwerten, sichtbaren Zeichen und Steuerzeichen abgefragt.

FN1 Ersatzwerttabelle#

wird verwendet, um den Ersatzwert von FN1 in EAN-128 festzulegen.

Regeln:

  • Standardwert: 7013, also Enter.

Einstellungsschritte:

  1. Scannen Sie Set FN1 Substitution Value.

  2. findet den Zielschlüsselwert in der ASCII-Zeichentabelle der aktuellen Hostschnittstelle

  3. Geben Sie den entsprechenden 4-stelligen Wert ein

Wenn Sie über Host-Befehle festlegen, setzen Sie zunächst die Key Category auf 1 und dann den dreistelligen Schlüsselwert.

Setup-Code#

Numerischer Setup-Code#

wird zur Eingabe numerischer Parameter wie Länge, Timeout, Helligkeit, Adresse usw. verwendet. Dieser Abschnitt enthält numerische Setup-Codes von 0 bis 9.

Nummer 0

Nummer 0#

Nummer 1

Nummer 1#

Nummer 2

Nummer 2#

Nummer 3

Nummer 3#

Nummer 4

Nummer 4#

Nummer 5

Nummer 5#

Nummer 6

Nummer 6#

Nummer 7

Nummer 7#

Nummer 8

Nummer 8#

Nummer 9

Nummer 9#

Eingabe abbrechen#

wird verwendet, um die aktuelle Eingabe rückgängig zu machen und beim Festlegen eines Werts von vorne zu beginnen.

Cancel

Eingabe abbrechen#