System Settings#
Default Parameter Settings#
Scan the following Parameter Barcodes to restore the factory default configuration, or switch to default configuration 1-5.
Note
The factory default configuration of the scan engine depends on the actual factory configuration.
Factory Default Settings#
Factory Default Settings#
Default Configuration 1-5#
Configuration |
Application Notes |
|---|---|
Default Configuration 1 |
Mainly for POS parameter configuration; the communication mode is serial, the trigger mode is key hold, and the terminator is disabled. |
Default Configuration 2 |
Mainly for self-service parameter configuration; the communication mode is USB KBW, the scan mode is Presentation Mode, and the terminator is carriage return + line feed ( |
Default Configuration 3 |
Mainly for Barcode Reader parameter configuration; the communication mode is USB KBW, the trigger mode is key hold, and the terminator is carriage return ( |
Default Configuration 4 |
The communication mode is serial 9600, the trigger mode is key hold, and the terminator is carriage return + line feed ( |
Default Configuration 5 |
Currently not enabled. |
Default Configuration 1#
Default Configuration 2#
Default Configuration 3#
Default Configuration 4#
Default Configuration 5#
Output Product Information#
Output Product Information#
Power Mode#
This parameter determines the power mode of the engine.
In low power mode, the scan engine automatically enters sleep after being idle for 800 ms (and can be awakened by a wake-up command). In continuous power mode, the scan engine stays awake after each decode attempt.
Continuous Power#
Low Power Mode#
Buzzer#
Buzzer Volume#
Scan the corresponding Parameter Barcode below to set the buzzer volume.
Low#
Medium#
* High#
Mute#
Buzzer Type#
* Passive Buzzer#
Active Buzzer#
Successful Decode Beep#
Scan the following barcode to set the success beep that sounds when the scan engine decodes successfully.
* Successful Decode Beep#
No Beep on Successful Decode#
Mute#
After mute is enabled, all beeps are turned off; after mute is disabled, the beeps are restored.
* Disable#
Enable#
Power-on Beep#
Disable#
Enable#
Parameter Entry Beep#
Disable#
* Enable#
Event Reporting#
This manual does not include the SSI command table. For event-report instructions, refer to the EVENT section in the external SSI Commands documentation.
Power-On Event#
Power-on event command: 05 F6 00 00 01 FF 04
* Disable#
Enable#
Trigger Decode Event#
When the scan engine is triggered to decode, indication can be provided through commands or GPIO pins; the GPIO pin indication remains low until decoding ends.
Trigger decode event command: 05 F6 00 00 02 FF 03
* Disable#
Enable Event#
Enable Pin Event#
Enable Event and GPIO Pin#
Heartbeat Control#
Heartbeat control supports the following operating modes.
Parameter Value |
Description |
|---|---|
|
Disable the heartbeat function. |
|
Send the heartbeat packet |
|
Send the heartbeat packet |
* Disable#
Heartbeat Without ACK#
Heartbeat With ACK#
Scan Configuration Barcodes#
When disabled, normal Parameter Barcodes are not decoded, but “Set Default Parameters” can still be decoded. Re-enable it by scanning “Enable Scan Parameter Barcodes”, setting default parameters, or using a serial command.
* Enable Scan Configuration Barcodes#
Disable Scan Configuration Barcodes#
Transmit Parameter Barcodes#
When enabled, the device outputs the data value of the Parameter Barcode while the barcode is scanned. Disabled by default.
Enable Transmit Parameter Barcodes#
* Disable Transmit Setting Barcodes#
Parameter Barcode Lock Mode#
Parameter Barcode password mode protects configuration operations with a lock. When enabled, you must first enter the correct Parameter Barcode password to unlock the device before scanning normal Parameter Barcodes. After one correct password entry, the device remains unlocked until the next power cycle.
Note
The password is a 2-digit number in the range 00-99.
Enable Parameter Barcode Lock Mode#
When the device switches from disabled to enabled Parameter Barcode password mode, password verification is required first. Password verification is also required before disabling this feature.
* Disable#
Enable#
Enter Parameter Barcode Password#
After scanning the following Parameter Barcode, scan a 2-digit Numeric Barcode to enter the password; pad with leading 0 if fewer than 2 digits are entered.
- Password Range
00-99
Enter Parameter Barcode Password#
Example
To enter password 68: scan this Parameter Barcode, then scan the Numeric Barcodes 6 and 8 in order.
To cancel an incorrect entry, scan Cancel Barcode.
Change Parameter Barcode Password#
The password can be changed only when Parameter Barcode password mode is enabled and password verification has succeeded (the device is unlocked).
Change Parameter Barcode Password#
Example
To set the new password to 96: scan this Parameter Barcode, then scan the Numeric Barcodes 9 and 6 in order.
To cancel an incorrect entry, scan Cancel Barcode.
Log Out Password#
After entering the correct password in password mode, scan this Parameter Barcode to clear the current unlocked state. Password entry is required again for subsequent configuration operations.
- Parameter number
0xF2 0xA9
Log Out Password#