Trigger Settings#

Trigger Mode#

Trigger mode selection/Trigger Mode#

Selects how the device starts decoding. Available options are:

  • Level Enters the decoding process after the trigger event starts, until the trigger ends, decoding is successful, or the “decoding session timeout” is reached.

  • Presentation Mode is automatically triggered when the device detects a target within the field of view and attempts to decode it. This mode is only available in decoding mode, and the target detection range is fixed under normal lighting conditions; the device will not enter low-power mode in this mode.

  • Host triggers the trigger signal by the host command; the actual physical trigger is still interpreted in the Level way.

  • Auto Aim Turns on the aiming pattern when motion is detected, and starts decoding after pulling the trigger; if there is no activity for 2 seconds, the aiming pattern automatically turns off.

  • Auto Aim with Illumination turns on the aiming pattern and internal lighting LED at the same time when motion is detected, and starts decoding after pulling the trigger; if there is no activity for 2 seconds, the aiming pattern and lighting LED automatically turn off.

Level

Level#

Presentation Mode

Presentation Mode#

Host

Host#

Auto Aim

Auto Aim#

Auto Aim with Illumination

Auto Aim with Illumination#

Continuous code reading and timeout#

Continuous code reading#

Used to control whether the device continues to try to read barcodes after a trigger.

  • Disable, default value

  • Enable

Disable continuous code reading

* Disable continuous code reading#

Enable continuous code reading

Enable continuous code reading#

Unique barcode reporting#

Used to control the reporting strategy of repeated content during continuous code reading.

  • Disable, default value

  • Enable

Disable reporting of unique barcodes

* Disable unique barcode reporting#

Enable unique barcode reporting

Enable unique barcode reporting#

Low light motion detection#

Used to adjust motion detection strategies in low-light environments.

  • No Low Light Motion Detection, default value

  • Low Light Motion Detection 1

  • Low Light Motion Detection 2

Disable low-light motion detection

* Disable low-light motion detection#

Low light motion detection level 1

Low light motion detection level 1#

Low light motion detection level 2

Low light motion detection level 2#

Demo mode view#

Sets the barcode search area in Presentation Mode. Available options are:

Small Field of View

Small Field of View#

Medium Field of View

* Medium Field of View#

Full Field of View

Full Field of View#

PDF priority timeout#

Used to set the waiting time for the device to first try to read PDF417 before reporting the one-dimensional code in the field of view after PDF Prioritization is enabled.

  • Value range: 0 to 5000 ms

  • Default value: 200 ms

  • Setting method: first scan the Parameter Barcode below, then scan the 4-digit barcode and enter the millisecond value

For example, when set to 400 ms, you need to scan the Parameter Barcode and then enter 0400.

Set PDF priority timeout

Set PDF priority timeout#

Same code repetition decoding interval#

Prevents the same barcode from being output repeatedly within a short period. The default interval is 0.6 seconds. Scan the Parameter Barcode, then scan the Numeric Barcodes to enter the required interval.

Set the same code repeated decoding interval

Set the same code repeated decoding interval#

Different code repetition decoding interval#

Used to limit the minimum interval when reading different barcodes continuously. According to the default parameter table, the default value is 0.2 seconds.

  • Value range: 0.1 to 9.9 seconds

  • Input method: After scanning the Parameter Barcode below, scan the 2-digit barcode

Set the different code repetition decoding interval

Set the different code repetition decoding interval#

Low power consumption and stop conditions#

Low power delay#

This parameter is used to set how long the device remains active after decoding is complete. After a scanning session ends, the device waits for a set time before entering low-power mode.

Note

Original description: This parameter only takes effect when Power Mode is set to low power mode.

Low power consumption delay value table#

Available values are:

  • 1 Second

  • 5 Seconds

  • 1 Minute

  • 5 Minutes

  • 15 Minutes

  • 1 Hour

1 second

1 second#

5 seconds

5 seconds#

1 minute

1 minute#

5 minutes

5 minutes#

15 minutes

15 minutes#

1 hour

1 hour#

If you need to set it to a value other than the above, the original text requires programming through the “Using Time Delay to Low Power Mode with SSI” method in the SSI interface.

Low power mode switch#

Source page: Page 102 Power Mode (Serial Hosts Only)

  • Continuous On Does not enter low power state after decoding attempt.

  • Low Power Mode Press the “low power delay” parameter to enter low power mode after decoding attempt.

Continuous On

Continuous On#

Low Power Mode

Low Power Mode#

Picklist mode#

Used to limit the device to decoding only bar codes located below the center area of the targeting pattern.

  • Disabled Always, default value

  • Enabled Always

Picklist is always disabled

* Always disable Picklist#

Always enable Picklist

Always enable Picklist#

Decoding session timeout#

Used to set the maximum duration of a single decoding attempt, ranging from 0.5 to 9.9 seconds in 0.1 seconds.

Set decoding session timeout

Set decoding session timeout#

Host Serial Response Timeout#

See also

This parameter belongs to the serial port and SSI communication parameters; when using the serial port host mode directly, the complete value and communication instructions should be checked in the complete PL5 module manual.

Host Character Timeout#

See also